skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Testing and Operation of the WR340 Waveguide Window in the APS Linac

Technical Report ·
DOI:https://doi.org/10.2172/815260· OSTI ID:815260

The Advanced Photon Source (APS) linac high-power switching system makes extensive use of SF6 pressurized, WR340-size waveguide, incorporating waveguide switches. A tunable, extra low return loss waveguide window has been developed to support interfacing the pressurized waveguide with the original waveguide, which is under vacuum. The tunable approach is able to consistently achieve a return loss of at least 40 dB. Test and alignment methods, performance, and initial operating experience are described.

Research Organization:
SLAC National Accelerator Lab., Menlo Park, CA (United States)
Sponsoring Organization:
USDOE Office of Science (US)
DOE Contract Number:
AC03-76SF00515
OSTI ID:
815260
Report Number(s):
SLAC-PUB-10116; TRN: US0304560
Resource Relation:
Other Information: Paper presented at LINAC 2002, Gyeongju (KR), 08/19/2002--08/23/2002; PBD: 11 Aug 2003
Country of Publication:
United States
Language: