The Advanced Photon Source (APS) linac high-power switching system makes extensive use of SF6 pressurized, WR340-size waveguide, incorporating waveguide switches. A tunable, extra low return loss waveguide window has been developed to support interfacing the pressurized waveguide with the original waveguide, which is under vacuum. The tunable approach is able to consistently achieve a return loss of at least 40 dB. Test and alignment methods, performance, and initial operating experience are described.

Research Organization:
Argonne National Lab., IL (US)
Sponsoring Organization:
US Department of Energy (US)
DOE Contract Number:
W-31-109-ENG-38
OSTI ID:
801598
Report Number(s):
ANL/ASD/CP-107472; TRN: US0205542
Resource Relation:
Conference: 21st International Linear Accelerator Conference (LINAC 2002), Gyeongju (KR), 08/19/2002--08/23/2002; Other Information: PBD: 29 Aug 2002