Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Improvement in brightness of multicusp-plasma ion source

Conference ·
OSTI ID:799567
The beam brightness of a multicusp-plasma ion source has been substantially improved by optimizing the source configuration and extractor geometry. The current density of a 2 keV He{sup +} beam extracted from a 7.5-cm-diameter source operating at 2.5 kW RF power is {approx}100 mA/cm{sup 2}, which is {approx}10 times larger than that of a beam extracted from a 5-cm-diameter source operating at 1 kW RF power. A smaller focused beam spot size is achieved with a counter-bored extractor instead of a conventional (''through-hole'') extractor, resulting another order of magnitude improvement in beam current density. Measured brightness can be as high as 440 A/cm{sup 2}Sr, which represents a 30 times improvement over prior work.
Research Organization:
Ernest Orlando Lawrence Berkeley National Laboratory, Berkeley, CA (US)
Sponsoring Organization:
USDOE Director, Office of Science (US)
DOE Contract Number:
AC03-76SF00098
OSTI ID:
799567
Report Number(s):
LBNL--49343; B& R YN0100000
Country of Publication:
United States
Language:
English

Similar Records

Ion energy spread and current measurements of the rf-driven multicusp ion source
Journal Article · Fri Feb 28 23:00:00 EST 1997 · Review of Scientific Instruments · OSTI ID:520953

Nanobeam production with the multicusp ion source
Journal Article · Mon Jan 31 23:00:00 EST 2000 · Review of Scientific Instruments · OSTI ID:20215404

RF Driven Multicusp H- Ion Source