A Criticality Alarm System (CAS) was developed at the Savannah River Site (SRS) beginning in 1964, which used an ionization chamber and battery - powered tube amplifier. Three generations of improvements are described here, to improve reliability, reduce maintenance cost, and eliminate false alarms. The original configuration for the CAS instrument (called Nuclear Incident Monitor-NIM model I) was a single chassis containing all components including the batteries and the detector, and a warning bell and light. To decrease the contamination potential of NIMs, the detector can now be removed from the chassis and remotely located for some installations. In the presently used second generation model II, each unit consists of an ion chamber with electrometer amplifier, voltage comparator circuits, battery and power supplies, monitoring circuits, and relay alarm circuits. The electrometer circuit is housed with the ion chamber in an aluminum enclosure. The remaining components are located in the main chassis. An alarm point of one R per Hour is adjustable over a narrow range for calibration purposes. Evacuation zones were determined on a 25 rad dose basis, and then modified to the 12 rad level.
- Research Organization:
- Savannah River Site (US)
- Sponsoring Organization:
- US Department of Energy (US)
- DOE Contract Number:
- AC09-96SR18500
- OSTI ID:
- 799457
- Report Number(s):
- WSRC-MS-2002-00539
- Country of Publication:
- United States
- Language:
- English
Similar Records
Nuclear incident monitor (31 Nov 1977) (Engineering Materials)
Coincidence logic modules for criticality alarming
An Approximate Method to Calculate 12 Rad zone
Miscellaneous
·
·
OSTI ID:5688416
Coincidence logic modules for criticality alarming
Technical Report
·
Mon Dec 31 23:00:00 EST 1979
·
OSTI ID:5392774
An Approximate Method to Calculate 12 Rad zone
Conference
·
Mon Jan 17 23:00:00 EST 2000
·
OSTI ID:750861