Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Nuclear incident monitor (31 Nov 1977) (Engineering Materials)

Miscellaneous ·
OSTI ID:5688416

An improved instrument to detect radiation emitted by the accidental assembly of a critical mass of fissionable material is described. The instrument is a gamma radiation monitor with audible and visible alarms which actuate when the monitor is exposed to a radiation rate exceeding one roentgen per hour. The instrument is ac powered with a backup self-contained battery. The detector is an air-filled ionization chamber. An electrometer amplifier is supplied to convert current from the chamber to a voltage signal. A voltage comparator monitors the voltage signal and energizes an alarm relay when chamber current exceeds a preset value. A fault detector monitors critical circuits and initiates a trouble alarm if a fault is detected. (FS)

Research Organization:
Du Pont de Nemours (E.I.) and Co., Aiken, SC (USA). Savannah River Lab.
OSTI ID:
5688416
Report Number(s):
CAPE-2648
Country of Publication:
United States
Language:
English