HIGH SO2 REMOVAL EFFICIENCY TESTING

Technical Report ·
DOI:https://doi.org/10.2172/794173· OSTI ID:794173
This final report describes the results of performance tests at six full-scale wet lime- and limestone-reagent flue gas desulfurization (FGD) systems. The objective of these tests was to evaluate the effectiveness of low capital cost sulfur dioxide (SO{sub 2}) removal upgrades for existing FGD systems as an option for complying with the provisions of the Clean Air Act Amendments of 1990. The upgrade options tested at the limestone-reagent systems included the use of organic acid additives (dibasic acid (DBA) and/or sodium formate) as well as increased reagent ratio (higher excess limestone levels in the recirculating slurry solids) and absorber liquid-to-gas ratio. One system also tested operating at higher flue gas velocities to allow the existing FGD system to treat flue gas from an adjacent, unscrubbed unit. Upgrade options for the one lime-based system tested included increased absorber venturi pressure drop and increased sulfite concentration in the recirculating slurry liquor.