Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

High SO{sub 2} removal efficiency testing: Results of DBA and sodium formate additive tests at Southwestern Electric Power company`s Pirkey Station

Technical Report ·
DOI:https://doi.org/10.2172/477733· OSTI ID:477733
Tests were conducted at Southwestern Electric Power Company`s (SWEPCo) Henry W. Pirkey Station wet limestone flue gas desulfurization (FGD) system to evaluate options for achieving high sulfur dioxide removal efficiency. The Pirkey FGD system includes four absorber modules, each with dual slurry recirculation loops and with a perforated plate tray in the upper loop. The options tested involved the use of dibasic acid (DBA) or sodium formate as a performance additive. The effectiveness of other potential options was simulated with the Electric Power Research Institute`s (EPRI) FGD PRocess Integration and Simulation Model (FGDPRISM) after it was calibrated to the system. An economic analysis was done to determine the cost effectiveness of the high-efficiency options. Results are-summarized below.
Research Organization:
Radian Corp., Austin, TX (United States)
Sponsoring Organization:
USDOE Assistant Secretary for Fossil Energy, Washington, DC (United States)
DOE Contract Number:
AC22-92PC91338
OSTI ID:
477733
Report Number(s):
DOE/PC/91338--T23; ON: DE97052396
Country of Publication:
United States
Language: