Laser: a Tool for Optimization and Enhancement of Analytical Methods

Thesis/Dissertation ·
DOI:https://doi.org/10.2172/793817· OSTI ID:793817
 [1]
  1. Iowa State Univ., Ames, IA (United States)
In this work, we use lasers to enhance possibilities of laser desorption methods and to optimize coating procedure for capillary electrophoresis (CE). We use several different instrumental arrangements to characterize matrix-assisted laser desorption (MALD) at atmospheric pressure and in vacuum. In imaging mode, 488-nm argon-ion laser beam is deflected by two acousto-optic deflectors to scan plumes desorbed at atmospheric pressure via absorption. All absorbing species, including neutral molecules, are monitored. Interesting features, e.g. differences between the initial plume and subsequent plumes desorbed from the same spot, or the formation of two plumes from one laser shot are observed. Total plume absorbance can be correlated with the acoustic signal generated by the desorption event. A model equation for the plume velocity as a function of time is proposed. Alternatively, the use of a static laser beam for observation enables reliable determination of plume velocities even when they are very high. Static scattering detection reveals negative influence of particle spallation on MS signal. Ion formation during MALD was monitored using 193-nm light to photodissociate a portion of insulin ion plume. These results define the optimal conditions for desorbing analytes from matrices, as opposed to achieving a compromise between efficient desorption and efficient ionization as is practiced in mass spectrometry. In CE experiment, we examined changes in a poly(ethylene oxide) (PEO) coating by continuously monitoring the electroosmotic flow (EOF) in a fused-silica capillary during electrophoresis. An imaging CCD camera was used to follow the motion of a fluorescent neutral marker zone along the length of the capillary excited by 488-nm Ar-ion laser. The PEO coating was shown to reduce the velocity of EOF by more than an order of magnitude compared to a bare capillary at pH 7.0. The coating protocol was important, especially at an intermediate pH of 7.7. The increase of pH in the cathodic (detection-end) buffer reservoir beyond pH ~8.0, e.g. as a result of electrolysis, had a large impact on the stability of the coating. This phenomenon may be used for the efficient and reliable fast regeneration of the column surface.
Research Organization:
Ames Lab., Ames, IA (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
W-7405-ENG-82
OSTI ID:
793817
Report Number(s):
IS-T--1800
Country of Publication:
United States
Language:
English

Similar Records

Investigations into ultraviolet matrix-assisted laser desorption
Thesis/Dissertation · Thu Jul 01 00:00:00 EDT 1993 · OSTI ID:10115006

Theoretical model of electroosmotic flow for capillary zone electrophoresis
Journal Article · Sun Oct 15 00:00:00 EDT 1995 · Analytical Chemistry (Washington) · OSTI ID:136269

Self-regulating dynamic control of electroosmotic flow in capillary electrophoresis
Journal Article · Sun Feb 28 23:00:00 EST 1993 · Analytical Chemistry (Washington); (United States) · OSTI ID:6217327