Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Gas permeation through a high density polyethylene microwave window

Journal Article · · J. Vac. Sci. Technol. A 11, 1584 (1993)
DOI:https://doi.org/10.1116/1.578508· OSTI ID:791703
Due to its low dielectric constant and low loss tangent, high density polyethylene (HDPE) has been selected for use as a high power microwave vacuum window in the Continuous Electron Beam Accelerator Facility cryounit. This window isolates the cryounit waveguide vacuum from the dry air in the external waveguide system. Gas permeation through the window will lead to cryopumping of the gas onto the cold waveguide walls and the cold ceramic window of the superconducting cavity. The gas load from permeation and outgassing of the window have to be minimized, due to the possibility of arcing when high power is applied through the waveguide. The outgassing and permeation of air through the 3.2 mm thick HDPE window were measured using the throughput method. A typical outgassing rate of 5.0 x 10{sup -1} Torr l/s/cm{sup 2} for samples baked out at 70 C was observed 20 h after pump down and bakeout. The gas load due to permeation through 34 cm{sup 2} of the window was 1.6 x 10 {sup -7} Torr l/s. The gas permeation through the 3.2 mm thick HDPE coated with a 300 nm barrier layer of SiO{sub x} was also investigated. No improvement was observed. It was presumably due to the presence of defects in the deposited SiO{sub x} layer.
Research Organization:
Thomas Jefferson National Accelerator Facility, Newport News, VA (US)
Sponsoring Organization:
USDOE Office of Energy Research (ER) (US)
DOE Contract Number:
AC05-84ER40150
OSTI ID:
791703
Report Number(s):
CEBAF-PR-93-055; DOE/ER/40150-2003
Journal Information:
J. Vac. Sci. Technol. A 11, 1584 (1993), Journal Name: J. Vac. Sci. Technol. A 11, 1584 (1993)
Country of Publication:
United States
Language:
English

Similar Records

Gas permeation through a high density polyethylene microwave window
Journal Article · Thu Jul 01 00:00:00 EDT 1993 · Journal of Vacuum Science and Technology, A (Vacuum, Surfaces and Films); (United States) · OSTI ID:6290179

Outgassing rate of the copper-plated beam tube for ISABELLE
Conference · Wed Dec 31 23:00:00 EST 1980 · OSTI ID:6466524

Comparison of outgassing rates from stainless steel, aluminum, and copper after bakeout under high vacuum and atmospheric pressure
Technical Report · Wed Aug 01 00:00:00 EDT 1973 · OSTI ID:4937347