Impact of the Low-Temperature Reactivity of Reillex(TM) HPQ on Actinide Processing
Journal Article
·
· Solvent Extraction and Ion Exchange
OSTI ID:787465
Reactive System Screening Tool(TM) data and a computational model are used to predict the impact of pressurization on a typical process-scale ion exchange column due to gases generated by a low temperature exothermic reaction (LTE). The LTE results from a reaction between nitric acid and the ethylbenzene pendant groups of the Reillex(TM) HPQ resin. This reaction would occur if the resin bed were inadvertently heated above 70 degrees C.
- Research Organization:
- Savannah River Site (US)
- Sponsoring Organization:
- US Department of Energy (US)
- DOE Contract Number:
- AC09-96SR18500
- OSTI ID:
- 787465
- Report Number(s):
- WSRC-MS-2001-00720
- Journal Information:
- Solvent Extraction and Ion Exchange, Journal Name: Solvent Extraction and Ion Exchange; ISSN 0736-6299; ISSN SEIEDB
- Country of Publication:
- United States
- Language:
- English
Similar Records
Evaluation of the Reactivity of Reillex HPQ in 64 Percent Nitric Acid
Characterization of Reillex{trademark} HPQ Polymer
Low-Temperature Exothermic Reaction of Reillex(TM) HPQ in Nitric Acid
Technical Report
·
Mon Feb 19 23:00:00 EST 2001
·
OSTI ID:775079
Characterization of Reillex{trademark} HPQ Polymer
Technical Report
·
Wed Dec 16 23:00:00 EST 1998
·
OSTI ID:4843
Low-Temperature Exothermic Reaction of Reillex(TM) HPQ in Nitric Acid
Journal Article
·
Tue Oct 02 00:00:00 EDT 2001
· Solvent Extraction and Ion Exchange
·
OSTI ID:787464