skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: PC/FRAM, Version 3.2 User Manual

Technical Report ·
DOI:https://doi.org/10.2172/7406· OSTI ID:7406

This manual describes the use of version 3.2 of the PC/FRAM plutonium isotopic analysis software developed in the Safeguards Science and Technology Group, NE-5, Nonproliferation and International Security Division Los Alamos National Laboratory. The software analyzes the gamma ray spectrum from plutonium-bearing items and determines the isotopic distribution of the plutonium 241Am content and concentration of other isotopes in the item. The software can also determine the isotopic distribution of uranium isotopes in items containing only uranium. The body of this manual descnies the generic version of the code. Special facility-specific enhancements, if they apply, will be described in the appendices. The information in this manual applies equally well to version 3.3, which has been licensed to ORTEC. The software can analyze data that is stored in a file on disk. It understands several storage formats including Canberra's S1OO format, ORTEC'S `chn' and `SPC' formats, and several ASCII text formats. The software can also control data acquisition using an MCA and then store the results in a file on disk for later analysis or analyze the spectrum directly after the acquisition. The software currently only supports the control of ORTEC MCB'S. Support for Canbema's Genie-2000 Spectroscopy Systems will be added in the future. Support for reading and writing CAM files will also be forthcoming. A versatile parameter fde database structure governs all facets of the data analysis. User editing of the parameter sets allows great flexibility in handling data with different isotopic distributions, interfering isotopes, and different acquisition parameters such as energy calibration, and detector type. This manual is intended for the system supervisor or the local user who is to be the resident expert. Excerpts from this manual may also be appropriate for the system operator who will routinely use the instrument.

Research Organization:
Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
Sponsoring Organization:
USDOE Office of Fissile Materials Disposition (MD)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
7406
Report Number(s):
LA-UR-99-998; ON: DE00007406
Country of Publication:
United States
Language:
English

Similar Records

PC/FRAM, Version 3. 2 User Manual
Technical Report · Tue Feb 23 00:00:00 EST 1999 · OSTI ID:7406

FRAM, Version 6.1 User Manual
Technical Report · Wed Jan 01 00:00:00 EST 2020 · OSTI ID:7406

FBL Outer Can Welder Analysis Software
Software · Mon Apr 21 00:00:00 EDT 2003 · OSTI ID:7406