Report on NRL measurements as a participant in the INDI. Final report
Technical Report
·
OSTI ID:7365168
NRL was invited to participate in the International Neutron Dosimetry Intercomparison (INDI) which took place during 1973 at the Raiological Research Accelerator Facility of Brookhaven National Laboratory, under the sponsorship of the International Commission on Radiation Units and Measurements. The source was a D-T generator of 15.5-MeV neutrons. Measurements were made only along the extended axis of the deutron beam; at 30 cm in free space, and at depths of 5, 10, and 20 cm in a 30 cm cubic water phantom positioned with its input face 20 cm from the neutron source. A 1-cc tissue-equivalent (TE) ion chamber was used with TE gas or air flowing through it to measure the total n+gamma dose in tissue, with appropriate corrections. Thermoluminescent dosimeters were employed to measure the gamma-ray dose component, assuming that the n/gamma sensitivity ratio measured in the NRL neutron beam (approx. 15 MeV average energy) was appropriate to the free-space measurement for the INDI. The gamma-ray dose component at 30 cm from the target is negligible in free space, probably not exceeding a few tenths of a percent of the total dose there. Within the phantom it is necessary to make a correction to the (n/gamma) sensitivities of the TLD's to account for the degradation of neutron energy with depth. The neutron spectrum at 5 cm, 10 cm, and 20 cm depth has been estimated by Herling through Monte Carlo calculations. (GRA)
- Research Organization:
- Naval Research Lab., Washington, D.C. (USA)
- OSTI ID:
- 7365168
- Report Number(s):
- AD-A-012339; NRL-MR-3051
- Country of Publication:
- United States
- Language:
- English
Similar Records
Nonparametric analysis of an international neutron dosimetry intercomparison
Dosimetry of neutron beams of a reactor in radiobiological examinations
THE VARIATION OF NEUTRON DOSE WITH DEPTH IN A TISSUE-EQUIVALENT PHANTOM
Conference
·
Wed Dec 31 23:00:00 EST 1975
·
OSTI ID:7347214
Dosimetry of neutron beams of a reactor in radiobiological examinations
Journal Article
·
Sun Dec 31 23:00:00 EST 1972
· Radiobiol.-Radiother., v. 14, no. 5, pp. 557-568
·
OSTI ID:4331869
THE VARIATION OF NEUTRON DOSE WITH DEPTH IN A TISSUE-EQUIVALENT PHANTOM
Journal Article
·
Sun Jul 01 00:00:00 EDT 1962
· Phys. in Med. Biol.
·
OSTI ID:4820437
Related Subjects
560152* -- Radiation Effects on Animals-- Animals
63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTANT EFFECTS ON LIVING ORGS. AND BIOL. MAT.
BARYONS
BIOLOGY
DOSIMETRY
ELEMENTARY PARTICLES
FERMIONS
HADRONS
LUMINESCENCE
MEDICINE
MONTE CARLO METHOD
NEUTRONS
NUCLEAR MEDICINE
NUCLEONS
RADIOBIOLOGY
RADIOLOGY
RADIOTHERAPY
THERAPY
THERMOLUMINESCENCE
63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTANT EFFECTS ON LIVING ORGS. AND BIOL. MAT.
BARYONS
BIOLOGY
DOSIMETRY
ELEMENTARY PARTICLES
FERMIONS
HADRONS
LUMINESCENCE
MEDICINE
MONTE CARLO METHOD
NEUTRONS
NUCLEAR MEDICINE
NUCLEONS
RADIOBIOLOGY
RADIOLOGY
RADIOTHERAPY
THERAPY
THERMOLUMINESCENCE