Using treatment verification film to detect geometric miss or localization error (LE), a follow-up analysis of LE for patients treated with extended mantle fields was made for the period 1973 to 1974. There were 451 treatment verification films for 19 patients reviewed and 67 errors were detected for an error rate of 15 percent. This rate represented a continued decrease compared to the previous rate of 36 percent (330 errors for 902 films) during 1969 to 1973. There was a continued reciprocal increase in number of films per patient per course of treatment which was thought, in part, to account for the improvement in technical precision. Reanalysis of localization error by site within the field showed a decrease in rate of error for the axillae from 1969 to 1973 to 1973 to 1974 and a relative increase in rate of error for the upper abdominal nodes. The decrease in error rate for the axillae was ascribed to increased attention to leaving adequate margin between pulmonary shield and axilla and the increase in error rate for upper abdominal nodes was ascribed to inadequate margin between shield and spine. The relative increase in errors for the upper abdominal nodes correlated with the physician who made the original decision about margin between spine and shield. Propagation of LE by site has been noted and can be prevented by monitoring treatment fields with verification film and correcting errors as they are noted.
- Research Organization:
- Washington Univ., School of Medicine, St. Louis
- OSTI ID:
- 7362372
- Conference Information:
- Journal Name: Cancer; (United States) Journal Volume: 37:6
- Country of Publication:
- United States
- Language:
- English
Similar Records
Localization error in the radiotherapy of Hodgkin's disease and malignant lymphoma with extended mantle fields. [99 lymphomas; 10 recurrent Hodgkins]
Film techniques in radiotherapy for treatment verification, determination of patient exit dose, and detection of localization error
Vertebral sarcoidosis: demonstration of bone involvement by computerized axial tomography
Conference
·
Mon Jul 01 00:00:00 EDT 1974
· Cancer; (United States)
·
OSTI ID:5237155
Film techniques in radiotherapy for treatment verification, determination of patient exit dose, and detection of localization error
Conference
·
Mon Dec 31 23:00:00 EST 1973
·
OSTI ID:4125422
Vertebral sarcoidosis: demonstration of bone involvement by computerized axial tomography
Journal Article
·
Wed Aug 01 00:00:00 EDT 1984
· South. Med. J.; (United States)
·
OSTI ID:6111201