Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Electric hydrogen recombiner special tests. [PWR]

Technical Report ·
OSTI ID:7353913
Westinghouse has produced an electric hydrogen recombiner to control hydrogen levels in reactor containments following a postulated loss-of-coolant accident. The recombiner underwent extensive testing for NRC qualification (see WCAP 7709-L and Supplements 1, 2, 3, 4). As a result, WCAP 7709-L and Supplements 1, 2, 3, and 4 have been accepted by the NRC for reference in applications not committed to IEEE-323-1974. Supplement 5 and the next supplement will demonstrate conformance to IEEE-323-1974. This supplement describes additional tests, beyond those necessary to qualify the system, which will be referenced in supplement 6. Each test has demonstrated a considerable margin of safety over required performance. Concurrently, the test results increased the fund of technical information on the electric hydrogen recombiner.
Research Organization:
Westinghouse Electric Corp., Pittsburgh, Pa. (USA)
OSTI ID:
7353913
Report Number(s):
WCAP-7820(Suppl.5)
Country of Publication:
United States
Language:
English