TATB performance and sensitivity. Period covered: July--September 1976

Technical Report ·
DOI:https://doi.org/10.2172/7317303· OSTI ID:7317303
Gap sensitivity tests continued on RX-03-BB. Results on materials which had been thermally cycled were consistent with density changes induced by the cycling. Two wedge tests were conducted with dry machined pure TATB at 1.84 g/cm/sup 3/. Sensitivity was essentially equivalent to RX-03-BB at 1.81 g/cm/sup 3/. Several cyclinder tests were conducted with RX-03-BB and pure TATB. Results are discussed.
Research Organization:
Mason and Hanger-Silas Mason Co., Inc., Amarillo, Tex. (USA)
OSTI ID:
7317303
Report Number(s):
MHSMP-76-46E