Performance and sensitivity testing of TATB. Period covered: January--March 1977
Routine gap testing (25 mm dia) of the LLL blends of RX-03-BB continued with Blends 12, 13, and 14. Blend 14 was distinctly the most sensitive one tested thus far. All three were formulated with Cordova TATB. Two lots of RX-03-BB formulated with Rocketdyne TATB were also tested and displayed no unusual behavior. Testing of LLL thermally conditioned samples of RX-03-BB Blend 2 continued. It appears that the sensitivity of some groups is not as great as would be expected based upon the final densities.
- Research Organization:
- Mason and Hanger-Silas Mason Co., Inc., Amarillo, TX (USA)
- DOE Contract Number:
- EY-76-C-04-0487
- OSTI ID:
- 7303063
- Report Number(s):
- MHSMP-77-18I
- Country of Publication:
- United States
- Language:
- English