skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Emission and absorption x-ray edges of Li

Abstract

Measurements of the K X-ray absorption and emission edges of Li are reported. They were made with the same spectrometer at the NBS storage ring and serve to establish a 0.1 eV separation between the edges with no possibility of instrument calibration error. These results are compared with recent theories of Almbladh and Mahan describing the effects of incomplete phonon relaxation about the core hole. It is concluded that these theories give a satisfactory explanation of the data.

Authors:
; ;
Publication Date:
Research Org.:
Oak Ridge National Lab., Tenn. (USA); National Bureau of Standards, Washington, D.C. (USA)
OSTI Identifier:
7295275
Report Number(s):
CONF-770935-1
TRN: 77-019137
DOE Contract Number:  
W-7405-ENG-26
Resource Type:
Conference
Resource Relation:
Conference: 5. international conference on vacuum ultraviolet radiation physics, Montpellier, France, 5 Sep 1977
Country of Publication:
United States
Language:
English
Subject:
36 MATERIALS SCIENCE; LITHIUM; X-RAY SPECTRA; ABSORPTION SPECTRA; EMISSION SPECTRA; PHONONS; RELAXATION; ALKALI METALS; ELEMENTS; METALS; QUASI PARTICLES; SPECTRA; 360104* - Metals & Alloys- Physical Properties

Citation Formats

Callcott, T A, Arakawa, E T, and Ederer, D L. Emission and absorption x-ray edges of Li. United States: N. p., 1977. Web.
Callcott, T A, Arakawa, E T, & Ederer, D L. Emission and absorption x-ray edges of Li. United States.
Callcott, T A, Arakawa, E T, and Ederer, D L. Sat . "Emission and absorption x-ray edges of Li". United States. https://www.osti.gov/servlets/purl/7295275.
@article{osti_7295275,
title = {Emission and absorption x-ray edges of Li},
author = {Callcott, T A and Arakawa, E T and Ederer, D L},
abstractNote = {Measurements of the K X-ray absorption and emission edges of Li are reported. They were made with the same spectrometer at the NBS storage ring and serve to establish a 0.1 eV separation between the edges with no possibility of instrument calibration error. These results are compared with recent theories of Almbladh and Mahan describing the effects of incomplete phonon relaxation about the core hole. It is concluded that these theories give a satisfactory explanation of the data.},
doi = {},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Sat Jan 01 00:00:00 EST 1977},
month = {Sat Jan 01 00:00:00 EST 1977}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share: