Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Analysis of heat flux measurement by circular foil gages in a mixed convection/radiation environment

Journal Article · · Journal of Heat Transfer (Transactions of the ASME (American Society of Mechanical Engineers), Series C); (United States)
DOI:https://doi.org/10.1115/1.2911202· OSTI ID:7281124
;  [1]
  1. Pennsylvania State Univ., University Park (United States)

Principles of heat flux measurement by circular foil heat flux sensors, also known as Gardon gages, are analyzed when the gages are subjected to a mixed convective/radiative heat flux. The specific objective of this work is to present the analysis and a methodology for estimating the error in the measurement of mixed convective-radiative heat flux, which is the difference between the true surface-sensed heat flux and the flux determined from the gage output using a calibration based on purely radiative heat flux.

OSTI ID:
7281124
Journal Information:
Journal of Heat Transfer (Transactions of the ASME (American Society of Mechanical Engineers), Series C); (United States), Journal Name: Journal of Heat Transfer (Transactions of the ASME (American Society of Mechanical Engineers), Series C); (United States) Vol. 113:4; ISSN 0022-1481; ISSN JHTRA
Country of Publication:
United States
Language:
English

Similar Records

Convection calibration method for local heat flux gages
Journal Article · Sat Jan 31 23:00:00 EST 1987 · J. Heat Transfer; (United States) · OSTI ID:6864389

Transient response of circular-foil heat-flux gages
Technical Report · Fri Jul 01 00:00:00 EDT 1983 · OSTI ID:5823511

Results of solar testing of circular foil heat-flux sensors at the White Sands Solar Furnace
Conference · Thu Dec 31 23:00:00 EST 1981 · OSTI ID:5093854