Convection calibration method for local heat flux gages
Journal Article
·
· J. Heat Transfer; (United States)
An apparatus for calibrating local heat flux gages in convective air flows is described. Heat transfer from a ''hot'' gage to a ''cold'' fluid was measured using a guarded hot-plate technique. The system was used to calibrate Gardon-type circular foil heat flux gates of 1/8 in. and 1/16 in. outer diameters. The reslts indicate that the calibration curves are nonlinear, which is different from the linear calibration obtained using the standard radiation technique. The degree of nonlinearity matches the analysis which accounts for the effect of the temperature distribution in the gage foil. The effect of this temperature distribution can be neglected in the standard radiation calibration but is often significant in convection applications. These results emphasize the importance of calibrating heat flux gates in thermal environments similar to those in which they will be used.
- Research Organization:
- Harris Corporation, GASD, Melbourne, FL 32902
- OSTI ID:
- 6864389
- Journal Information:
- J. Heat Transfer; (United States), Journal Name: J. Heat Transfer; (United States) Vol. 109:1; ISSN JHTRA
- Country of Publication:
- United States
- Language:
- English
Similar Records
Analysis of heat flux measurement by circular foil gages in a mixed convection/radiation environment
Transient response of circular-foil heat-flux gages
Study of heat flux gages using sensitivity analysis
Journal Article
·
Thu Oct 31 23:00:00 EST 1991
· Journal of Heat Transfer (Transactions of the ASME (American Society of Mechanical Engineers), Series C); (United States)
·
OSTI ID:7281124
Transient response of circular-foil heat-flux gages
Technical Report
·
Fri Jul 01 00:00:00 EDT 1983
·
OSTI ID:5823511
Study of heat flux gages using sensitivity analysis
Conference
·
Sat Aug 01 00:00:00 EDT 1998
·
OSTI ID:674755