skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: In situ remediation of contaminated ground water: The funnel-and-gate system

Journal Article · · Ground Water; (United States)
;  [1]
  1. Univ. of Waterloo, Ontario (Canada). Waterloo Centre for Groundwater Research

The funnel-and-gate system for in situ treatment of contaminant plumes consists of low hydraulic conductivity cutoff walls with gaps that contain in situ reactors, such as reactive porous media-, that remove contaminants by abiotic or biological processes. Funnel-and-gate systems can be installed at the front of plumes to prevent further plume growth, or immediately downgradient of contaminant source zones to prevent contaminants from moving into plumes. Cutoff walls (the funnel) modify flow patterns so that ground water flows primarily through high conductivity gaps (the gates). This approach is largely passive in that after installation, in situ reactors are intended to function with little or no maintenance for long periods. This approach contrasts with the energy and maintenance-intensive character of pump-and-treat systems. This paper describes the funnel-and-gate concept, and uses two-dimensional computer simulations to illustrate the effects of cutoff wall and gate configuration on capture zone size and shape and on the residence time for reaction of contaminants in gates.

OSTI ID:
7274428
Journal Information:
Ground Water; (United States), Vol. 32:3; ISSN 0017-467X
Country of Publication:
United States
Language:
English