A 110 GHz ozone radiometer with a cryogenic planar Schottky mixer

Journal Article · · IEEE Transactions on Microwave Theory and Techniques (Institute of Electrical and Electronics Engineers); (United States)
DOI:https://doi.org/10.1109/22.260711· OSTI ID:7273179
; ;  [1]; ; ;  [2]
  1. Helsinki Univ. of Technology, Espoo (Finland)
  2. Russian Academy of Science, Nizhny-Novgorod (Russian Federation)
A total power radiometer is presented for monitoring of the stratospheric ozone spectral line at 110 GHz. Special features such as a cooled planar Schottky mixer as the front end and efficient reduction of standing waves in the quasi-optics, are discussed in detail. The noise temperature of the receiver is 530 K (SSB), and the total bandwidth of the receiver is 1 GHz. A dual acousto-optical spectrometer is used for the signal detection.