Reliability and operating experience of the LAMPF 805-MHz rf system
Over 850,000 hours have been accumulated on the klystrons and modulators that constitute the LAMPF 805-MHz rf system. The 1-1/4 MW klystrons, the floating-deck modulators, and the modulator triodes are described. The operating data are summarized, and the fault and failure modes are tabulated for the three major components of the system. The high-voltage processing and other maintenance required to keep this 86-kV system operating reliably are described. The tube failure rates, tube fault rates, and modulator fault rates are presented. The mean time to failures is greater than 56,500 h for the klystrons and greater than 40,600 h for the modulator triodes. The steps taken to produce such good reliability are discussed.
- Research Organization:
- Los Alamos Scientific Lab., N.Mex. (USA)
- DOE Contract Number:
- W-7405-ENG-36
- OSTI ID:
- 7262135
- Report Number(s):
- LA-UR-76-1666; CONF-760924-1
- Country of Publication:
- United States
- Language:
- English
Similar Records
LAMPF 805 MHz RF system
Design and performance of the LAMPF 1-1/4 MW klystron modulator
Upgrading the LAMPF 201 MHz RF generators
Conference
·
Wed Dec 31 23:00:00 EST 1980
·
OSTI ID:6609436
Design and performance of the LAMPF 1-1/4 MW klystron modulator
Conference
·
Tue Apr 30 00:00:00 EDT 1974
·
OSTI ID:4419181
Upgrading the LAMPF 201 MHz RF generators
Conference
·
Wed Mar 31 23:00:00 EST 1993
·
OSTI ID:10142750
Related Subjects
43 PARTICLE ACCELERATORS
430300* -- Particle Accelerators-- Auxiliaries & Components
ACCELERATORS
ELECTRON TUBES
ELECTRONIC CIRCUITS
ELECTRONIC EQUIPMENT
FAILURES
KLYSTRONS
LAMPF LINAC
LINEAR ACCELERATORS
MAINTENANCE
MESON FACTORIES
MICROWAVE EQUIPMENT
MICROWAVE TUBES
OPERATION
RELIABILITY
RF SYSTEMS
TRIODE TUBES
430300* -- Particle Accelerators-- Auxiliaries & Components
ACCELERATORS
ELECTRON TUBES
ELECTRONIC CIRCUITS
ELECTRONIC EQUIPMENT
FAILURES
KLYSTRONS
LAMPF LINAC
LINEAR ACCELERATORS
MAINTENANCE
MESON FACTORIES
MICROWAVE EQUIPMENT
MICROWAVE TUBES
OPERATION
RELIABILITY
RF SYSTEMS
TRIODE TUBES