LAMPF 805 MHz RF system
The LAMPF 805 MHz RF system was available 97.7% of the scheduled beam time (2432 h) during experiment cycles 25 and 26, January to June 1980. The tube lifetimes, operation, maintenance, and processing which lead to this reliability are discussed. The LPT-44 triode, used as a switchtube in the modulator has a mean life > 16,000 h. The 805 MHz L-5120A klystron has a mean life > 10,000 h and the 805 MHz klystron VA-862A apparently will have a mean life > 50,000 h. Tube life data is plotted. Fault and failure modes are discussed and tabulated.
- Research Organization:
- Los Alamos National Lab., NM (USA)
- DOE Contract Number:
- W-7405-ENG-36
- OSTI ID:
- 6609436
- Report Number(s):
- LA-UR-81-636; CONF-810314-1
- Country of Publication:
- United States
- Language:
- English
Similar Records
Reliability and operating experience of the LAMPF 805-MHz rf system
Developments and directions in 200 MHz very high power RF at LAMPF
delta. t tuneup procedure for the LAMPF 805-MHz linac
Conference
·
Wed Dec 31 23:00:00 EST 1975
·
OSTI ID:7262135
Developments and directions in 200 MHz very high power RF at LAMPF
Conference
·
Mon Dec 31 23:00:00 EST 1990
·
OSTI ID:5333626
delta. t tuneup procedure for the LAMPF 805-MHz linac
Technical Report
·
Sat May 01 00:00:00 EDT 1976
·
OSTI ID:7353211
Related Subjects
43 PARTICLE ACCELERATORS
430303* -- Particle Accelerators-- Experimental Facilities & Equipment
ACCELERATORS
ELECTRON TUBES
ELECTRONIC EQUIPMENT
EQUIPMENT
KLYSTRONS
LAMPF LINAC
LINEAR ACCELERATORS
MESON FACTORIES
MICROWAVE EQUIPMENT
MICROWAVE TUBES
PERFORMANCE
RELIABILITY
RF SYSTEMS
SERVICE LIFE
430303* -- Particle Accelerators-- Experimental Facilities & Equipment
ACCELERATORS
ELECTRON TUBES
ELECTRONIC EQUIPMENT
EQUIPMENT
KLYSTRONS
LAMPF LINAC
LINEAR ACCELERATORS
MESON FACTORIES
MICROWAVE EQUIPMENT
MICROWAVE TUBES
PERFORMANCE
RELIABILITY
RF SYSTEMS
SERVICE LIFE