Inertia welding (IW) is being evaluated as an alternative to gas-tungsten-arc (GTA) welding, for welding Mark 31 slugs. To demonstrate IW, 40 production (GTA) slugs rejected for pinholes and poor bonds were used. After welding, the slugs were autoclave tested. No autoclave failures occurred. (DLC)