Impact of heating and air conditioning system operation and leakage on ventilation and intercompartment transport: Studies in unoccupied and occupied Tennessee Valley homes
Journal Article
·
· Journal of the Air and Waste Management Association; (USA)
OSTI ID:7157553
- Oak Ridge National Lab., TN (USA)
Forced-air heating and air conditioning (HAC) systems caused an average and maximum increase in air infiltration rates of 1.8- and 4.3-fold, respectively, during brief whole-house studies of tracer gas decay in 39 occupied houses. An average increase in air infiltration rate of 0.33 +/- 0.37 h-1 corresponded to an incremental air leak of 240 m3/h, based on approximate house volume. More detailed tracer gas decay studies were performed in basement, kitchen and bedroom locations of six homes with low air infiltration rates (i.e., less than 0.25 h-1). The HAC mixed the indoor air efficiently between measurement sites. HAC operation also caused 1.1- to 3.6-fold increases in air infiltration rates, corresponding to absolute increases of 0.02 to 0.1 h-1. In an unoccupied research house, three-fold increases in average air infiltration rate with HAC operation (i.e., from 0.13 to 0.36 h-1) were reduced to two-fold (i.e., from 0.10 to 0.18 h-1) by sealing the external HAC unit and crawlspace ductwork system. This sealing also resulted in a 30 percent reduction in crawlspace-to-indoor transport rates with the HAC turned on. Blower door tests indicated a less than 20 percent reduction in house leakage area.
- OSTI ID:
- 7157553
- Journal Information:
- Journal of the Air and Waste Management Association; (USA), Journal Name: Journal of the Air and Waste Management Association; (USA) Vol. 40:2; ISSN JAWAE; ISSN 1047-3289
- Country of Publication:
- United States
- Language:
- English
Similar Records
Air infiltration rates in pre- and post-weatherized houses
Air exchange rate measurements in an IAQ test house
Indoor air pollution in four cities in China
Journal Article
·
Wed May 01 00:00:00 EDT 1985
· J. Air Pollut. Control Assoc.; (United States)
·
OSTI ID:5082122
Air exchange rate measurements in an IAQ test house
Technical Report
·
Tue Sep 01 00:00:00 EDT 1998
·
OSTI ID:642845
Indoor air pollution in four cities in China
Journal Article
·
Sat Nov 30 23:00:00 EST 1991
· Biomedical and Environmental Sciences; (United States)
·
OSTI ID:5719690
Related Subjects
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION
320106* -- Energy Conservation
Consumption
& Utilization-- Building Equipment-- (1987-)
320107 -- Energy Conservation
Consumption
& Utilization-- Building Systems-- (1987-)
AIR CONDITIONING
AIR INFILTRATION
AIR POLLUTION
BUILDINGS
EFFICIENCY
ENERGY SYSTEMS
FEDERAL REGION IV
HEATING SYSTEMS
HOUSES
LEAKS
NORTH AMERICA
POLLUTION
RESIDENTIAL BUILDINGS
TENNESSEE
USA
VENTILATION
320106* -- Energy Conservation
Consumption
& Utilization-- Building Equipment-- (1987-)
320107 -- Energy Conservation
Consumption
& Utilization-- Building Systems-- (1987-)
AIR CONDITIONING
AIR INFILTRATION
AIR POLLUTION
BUILDINGS
EFFICIENCY
ENERGY SYSTEMS
FEDERAL REGION IV
HEATING SYSTEMS
HOUSES
LEAKS
NORTH AMERICA
POLLUTION
RESIDENTIAL BUILDINGS
TENNESSEE
USA
VENTILATION