Bayesian Zero-Failure (BAZE) reliability demonstration testing procedure and its application to a Rankine dynamic radioisotope power conversion system

Technical Report ·
DOI:https://doi.org/10.2172/7140632· OSTI ID:7140632
A Bayesian Zero-Failure (BAZE) reliability demonstration testing procedure is developed. The procedure may be used to verify component failure rates associated with both real-time dependent and cycle-dependent chance failure mechanisms. A constant falure-rate model with a gamma prior distribution is assumed. The procedure is used to obtain sample test plans for components of a proposed Rankine power conversion system.
Research Organization:
Los Alamos Scientific Lab., N.Mex. (USA)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
7140632
Report Number(s):
LA-6421-MS
Country of Publication:
United States
Language:
English