Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Infrared thermography of the DIII-D divertor targets

Journal Article · · Rev. Sci. Instrum.; (United States)
DOI:https://doi.org/10.1063/1.1140040· OSTI ID:7123460

The power flow to the DIII-D divertor targets is routinely measured using infrared (IR) thermography. An IR television camera sensitive to radiation in the 8--12-..mu..m range views the divertor region using a set of germanium optics. Digital signal processing is used to extract the desired surface temperature profiles from the analog data (approx. =12 Mbytes) stored on videotape. Inversion of these data using a simple matrix formulation of the inverse heat conduction problem then yields the incident heat flux as a function of space and time. Results from a DIII-D discharge are included.

Research Organization:
Lawrence Livermore National Laboratory, Livermore, California 94550
OSTI ID:
7123460
Journal Information:
Rev. Sci. Instrum.; (United States), Journal Name: Rev. Sci. Instrum.; (United States) Vol. 59:8; ISSN RSINA
Country of Publication:
United States
Language:
English