Infrared thermography of the DIII-D divertor targets
Conference
·
OSTI ID:6986067
The power flow to the DIII-D divertor targets is routinely measured using infrared (IR) thermography. An IR television camera sensitive to radiation in the 8--12 ..mu..m range views the divertor region using a set of germanium optics. Digital signal processing is used to extract the desired surface temperature profiles from the analog data (approx. =20 Mbytes) stored on videotape. Inversion of these data using a simple matrix formulation of the inverse heat conduction problem then yields the incident heat flux as a function of space and time. Results from a DIII-D discharge are included. 5 refs., 4 figs.
- Research Organization:
- General Atomics Co., San Diego, CA (USA)
- DOE Contract Number:
- AC03-84ER51044
- OSTI ID:
- 6986067
- Report Number(s):
- GA-A19183; CONF-880364-26; ON: DE88010829
- Country of Publication:
- United States
- Language:
- English