Standard test method for oxidant (ozone) content of the atmosphere

Journal Article · · Annu. Book ASTM Stand.; (United States)
OSTI ID:7087612
This method covers the determination of low concentrations of oxidant (ozone) in the atmosphere. The method is not specific for ozone since other oxidizing and reducing substances interfere. The interference of sulfur dioxide (SO/sub 2/) and nitrogen dioxide (NO/sub 2/) can be eliminated during the analysis of the sample. The limit for detection of ozone by the method described is 1 to 16 ..mu..g. For samples of higher concentration, appropriate dilutions with the absorbing solution must be made. Micro amounts of oxidant (ozone) are collected by absorption in a solution of alkaline potassium iodide. The iodine equivalent to the concentration of oxidant present in the air released after acidification is determined precisely and rapidly spectrophotometrically by measuring the absorption of the triiodide ion at 352 nm.
OSTI ID:
7087612
Journal Information:
Annu. Book ASTM Stand.; (United States), Journal Name: Annu. Book ASTM Stand.; (United States) Vol. 26; ISSN ASTSA
Country of Publication:
United States
Language:
English