Assay for pyridoxal phosphate in 10 microliters of human venous and capillary blood plasma

Journal Article · · Fed. Proc., Fed. Am. Soc. Exp. Biol.; (United States)
OSTI ID:7035405
Plasma pyridoxal phosphate (PLP) concentrations of venous (V), capillary (C) and V-blood drawn into a hematocrit (Hct) tube (VH) and processed exactly as the C-blood were determined by the standard (STD) or a modified micro (MCR) tyrosine apodecarboxylase procedure. Compared to the STD the MCR uses 20 times the spec. act. of /sup 14/C-tyrosine, a 40 vs 20 min reaction time and 10 vs 850 ..mu..l plasma. Conclusions indicate that STD and MCR generate equivalent values. C-plasma gives slightly higher PLP concentrations than V-plasma which may be related to packing of blood cells in the Hct tube.
Research Organization:
Dept. of Agriculture, Beltsville, MD
OSTI ID:
7035405
Report Number(s):
CONF-8604222-
Journal Information:
Fed. Proc., Fed. Am. Soc. Exp. Biol.; (United States), Journal Name: Fed. Proc., Fed. Am. Soc. Exp. Biol.; (United States) Vol. 45:4; ISSN FEPRA
Country of Publication:
United States
Language:
English