Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Correlation of secondary-side IGA/SCC degradation of recirculating steam generator tubing with the on-line addition of boric acid

Technical Report ·
OSTI ID:7022565
; ;  [1]
  1. Dominion Engineering, Inc., McLean, VA (United States)
A survey of field data indicates that the on-line addition of boric acid can reduce the rate of intergranular attack and stress corrosion cracking (IGA/SCC) within the hot leg tube support crevices for some PWR steam generators. However, the beneficial effect was not seen at all surveyed plants. 68 refs., 12 tabs., 12 refs.
Research Organization:
Electric Power Research Inst., Palo Alto, CA (United States); Dominion Engineering, Inc., McLean, VA (United States)
Sponsoring Organization:
EPRI; Electric Power Research Inst., Palo Alto, CA (United States)