Correlation of secondary-side IGA/SCC degradation of recirculating steam generator tubing with the on-line addition of boric acid
Technical Report
·
OSTI ID:10177653
- Dominion Engineering, Inc., McLean, VA (United States)
A survey of field data indicates that the on-line addition of boric acid can reduce the rate of intergranular attack and stress corrosion cracking (IGA/SCC) within the hot leg tube support crevices for some PWR steam generators. However, the beneficial effect was not seen at all surveyed plants. 68 refs., 12 tabs., 12 refs.
- Research Organization:
- Electric Power Research Inst., Palo Alto, CA (United States); Dominion Engineering, Inc., McLean, VA (United States)
- Sponsoring Organization:
- Electric Power Research Inst., Palo Alto, CA (United States)
- OSTI ID:
- 10177653
- Report Number(s):
- EPRI-TR--101010; ON: UN92040683
- Country of Publication:
- United States
- Language:
- English
Similar Records
Correlation of secondary-side IGA/SCC degradation of recirculating steam generator tubing with the on-line addition of boric acid
An Investigation of the Mechanism of IGA/SCC of Alloy 600 in Corrosion Accelerating Heated Crevice Environments. Technical Progress Report
Effect of boric acid on intergranular corrosion and on hideout return efficiency of sodium in the tube support plate crevices
Technical Report
·
Sat Aug 01 00:00:00 EDT 1992
·
OSTI ID:7022565
An Investigation of the Mechanism of IGA/SCC of Alloy 600 in Corrosion Accelerating Heated Crevice Environments. Technical Progress Report
Technical Report
·
Thu Dec 31 23:00:00 EST 1998
·
OSTI ID:762745
Effect of boric acid on intergranular corrosion and on hideout return efficiency of sodium in the tube support plate crevices
Book
·
Sat Dec 30 23:00:00 EST 1995
·
OSTI ID:203816
Related Subjects
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS
210200
36 MATERIALS SCIENCE
360105
BORIC ACID
CORROSION
CORROSION AND EROSION
CORROSION INHIBITORS
EDDY CURRENT TESTING
FAILURES
INTERGRANULAR CORROSION
NUCLEAR POWER PLANTS
POWER REACTORS
NONBREEDING
LIGHT-WATER MODERATED
NONBOILING WATER COOLED
PWR TYPE REACTORS
STEAM GENERATORS
STRESS CORROSION
SURVEYS
TUBES
210200
36 MATERIALS SCIENCE
360105
BORIC ACID
CORROSION
CORROSION AND EROSION
CORROSION INHIBITORS
EDDY CURRENT TESTING
FAILURES
INTERGRANULAR CORROSION
NUCLEAR POWER PLANTS
POWER REACTORS
NONBREEDING
LIGHT-WATER MODERATED
NONBOILING WATER COOLED
PWR TYPE REACTORS
STEAM GENERATORS
STRESS CORROSION
SURVEYS
TUBES