Quantitative adhesion measures of multilayer films: Part II. Indentation of W/Cu, W/W, Cr/W

Journal Article · · Journal of Materials Research
;  [1];  [2]
  1. Department of Chemical Engineering and Materials Science, University of Minnesota, Minneapolis, Minnesota 55455 (United States)
  2. Sandia National Laboratories, Livermore, California 94551 (United States)

Sputtered copper and tungsten thin films both with and without tungsten and chromium superlayers were tested by using nanoindentation probing to initiate and drive delamination. The adhesion energies of the films were calculated from the induced delaminations using the analysis presented in {open_quotes}Quantitative adhesion measures of multilayer films: Part I. Indentation mechanics.{close_quotes} Copper films ranging in thickness from 150 to 1500 nm in the as-sputtered condition had measured adhesion energies ranging from 0.2 to 2 J/m{sup 2}, commensurate with the thermodynamic work of adhesion. Tungsten films ranging in thickness from 500 to 1000 nm in the as-sputtered condition had measured adhesion energies ranging from 5 to 15 J/m{sup 2}. The superlayer was shown to induce radial cracking when under residual tension, resulting in underestimation of the adhesion energy when the film was well adhered. Under conditions of weak adherence or residual compression, the superlayer provided an excellent means to induce a delamination and allowed an accurate and reasonably precise quantitative measure of thin film adhesion. {copyright} {ital 1999 Materials Research Society.}

OSTI ID:
701000
Journal Information:
Journal of Materials Research, Journal Name: Journal of Materials Research Journal Issue: 7 Vol. 14; ISSN JMREEE; ISSN 0884-2914
Country of Publication:
United States
Language:
English