A comparison of ROChem reverse osmosis and spiral wound reverse osmosis membrane modules

Technical Report ·
DOI:https://doi.org/10.2172/6994228· OSTI ID:6994228
Testing of the ROChem Disc Tube[reg sign] reverse osmosis (RO) module's performance on biologically active feed waters has been completed. Both the ROChem module (using Filmtec standard-rejection seawater membranes) and the Filmtec spiral-wound membrane module (using Filmtec high-rejection seawater membranes) were tested with stimulant solutions containing typical bacteria and metal hydroxide levels found in the F/H Effluent Treatment Facility (ETF) influent. Results indicate that the ROChem module gave superior performance over the spiral-wound module. Water flux losses were reduced by over 30% for water recoveries above 40%.
Research Organization:
Westinghouse Savannah River Co., Aiken, SC (United States)
Sponsoring Organization:
DOE; USDOE, Washington, DC (United States)
DOE Contract Number:
AC09-89SR18035
OSTI ID:
6994228
Report Number(s):
WSRC-RP-92-239; ON: DE93002806
Country of Publication:
United States
Language:
English