A comparison of ROChem reverse osmosis and spiral wound reverse osmosis membrane modules
Testing of the ROChem Disc Tube{reg_sign} reverse osmosis (RO) module`s performance on biologically active feed waters has been completed. Both the ROChem module (using Filmtec standard-rejection seawater membranes) and the Filmtec spiral-wound membrane module (using Filmtec high-rejection seawater membranes) were tested with stimulant solutions containing typical bacteria and metal hydroxide levels found in the F/H Effluent Treatment Facility (ETF) influent. Results indicate that the ROChem module gave superior performance over the spiral-wound module. Water flux losses were reduced by over 30% for water recoveries above 40%.
- Research Organization:
- Westinghouse Savannah River Co., Aiken, SC (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC09-89SR18035
- OSTI ID:
- 10191871
- Report Number(s):
- WSRC-RP--92-239; ON: DE93002806
- Country of Publication:
- United States
- Language:
- English