A comparison of ROChem reverse osmosis and spiral wound reverse osmosis membrane modules

Technical Report ·
DOI:https://doi.org/10.2172/10191871· OSTI ID:10191871
Testing of the ROChem Disc Tube{reg_sign} reverse osmosis (RO) module`s performance on biologically active feed waters has been completed. Both the ROChem module (using Filmtec standard-rejection seawater membranes) and the Filmtec spiral-wound membrane module (using Filmtec high-rejection seawater membranes) were tested with stimulant solutions containing typical bacteria and metal hydroxide levels found in the F/H Effluent Treatment Facility (ETF) influent. Results indicate that the ROChem module gave superior performance over the spiral-wound module. Water flux losses were reduced by over 30% for water recoveries above 40%.