Baseline conditions for orifice meter calibration, Topical report, February 1990-July 1992

Technical Report ·
OSTI ID:6949792

The study analyzes nominal 102 mm (4') baseline orifice discharge coefficient, data for Beta ratios between 0.2 and 0.75 from several independent laboratories in the United States and Europe. Graphs of Cd vs. Reynolds number are presented for each data set, and each data set was analyzed to determine the statistical mean deviation and standard deviation from the American Gas Association (A.G.A.) Report No. 3 orifice coefficient equation. Baseline orifice Cd data taken in the Gas Research Institute Metering Research Facility (MRF) flowing nitrogen agree well with comparable high accuracy baseline data from the other laboratories. For Beta ratio values between 0.2 and 0.67, the mean deviation of MRF baseline data from the A.G.A. Report No. 3 orifice equation ranges from 0.05% to 0.20%. Vertical and horizontal profiles of mean axial velocity and axial turbulence intensity were measured in the MRF under typical baseline flow conditions for meter run lengths of 45 D and 100 D. The baseline profiles of mean axial velocity satisfy the International Standards Organization (ISO) 5167 requirement of less than + or - 5% variation from a fully developed, turbulent flow velocity profile.