Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

POLYFAIL: a program for identification of multiple fuel failures with gas tagging

Technical Report ·
DOI:https://doi.org/10.2172/6941999· OSTI ID:6941999
This report describes the development of the computer code POLYFAIL for identification of fuel failures in fast reactors or light-water reactors that use gas tagging. POLYFAIL implements a sophisticated numerical algorithm known as the method of barycentric coordinates. The code can treat problems involving up to four simultaneous tag releases in a tagging system characterized by three independent tag ratios. The sensitivity of the multiple-failure-resolution technique has been optimized by incorporation of a newly developed ratio weighting scheme. Several example problems are provided to demonstrate operation of the code under single-leaker and various postulated multiple-leaker situations.
Research Organization:
Argonne National Laboratory (ANL), Argonne, IL (United States)
DOE Contract Number:
W-31109-ENG-38
OSTI ID:
6941999
Report Number(s):
ANL-80-87
Country of Publication:
United States
Language:
English