Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Effects of imperfections on the dynamic aperture and closed orbit of the IPNS Upgrade synchrotron

Conference ·
OSTI ID:69110
Magnet imperfections and misalignments are analyzed in terms of their effects on the dynamic aperture and closed orbit of the IPNS Upgrade synchrotron. The dynamic aperture is limited primarily by the presence of chromaticity-correcting sextupoles. With the sextupoles energized to the values required to adjust the chromaticities to zero, further reductions of the dynamic aperture caused by dipole strength and roll errors, quadrupole strength and alignment errors, and higher-order multipole errors are studied by tracking. Design specifications for the dipole corrector magnets are obtained and the dynamic aperture is studied before and after correction of the closed orbit. The use of harmonic-correcting sextupoles to reduce the amplitude-dependent tune shifts driven by the chromaticity-correcting sextupoles is investigated.
Research Organization:
Argonne National Lab., IL (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
W-31109-ENG-38
OSTI ID:
69110
Report Number(s):
ANL/ASD/CP--85027; CONF-950512--161; ON: DE95012917
Country of Publication:
United States
Language:
English

Similar Records

Error Correction for the JLEIC Ion Collider Ring
Conference · Sun May 01 00:00:00 EDT 2016 · OSTI ID:1331984

CDR (Conceptual Design Report) lattice aperture limitations due to magnetic imperfections in the IR quadrupole triplets
Technical Report · Sat Jan 31 23:00:00 EST 1987 · OSTI ID:6732940

Establishment of a tolerance budget for the Advanced Photon Source storage ring