Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Establishment of a tolerance budget for the Advanced Photon Source storage ring

Conference ·
OSTI ID:10162296
The limitations on the dynamic aperture of the Advanced Photon Source storage ring due to magnet misalignments and fabrication errors are presented. The reduction of the dynamic aperture is analyzed first for each error considered individually, and then for combined error multipole fields in dipole, quadrupole, and sextupole magnets, excluding and including magnet misalignments. Since misalignments of the strong quadrupoles in the ring induce large orbit distortions, the effects on the dynamic aperture are investigated before and after orbit correction. Effects of off-momentum particles and the tune dependence with momentum are also presented. This extensive analysis leads to the establishment of a tolerance budget. With all the errors set at the tolerance level and with the orbit distortions corrected, the dynamic aperture reduction is no greater than 50% of that of the ideal machine.
Research Organization:
Argonne National Lab., IL (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
W-31109-ENG-38
OSTI ID:
10162296
Report Number(s):
ANL/ASD/CP--78298; CONF-930511--148; ON: DE93015165
Country of Publication:
United States
Language:
English