Maximum voltage gradient, uniformity and brightness of dispenser cathodes
Conference
·
OSTI ID:6909830
Initial measurements of current uniformity and intrinsic cathode brightness are presented a 5.1 cm diameter osmium alloy coated dispenser cathode. The data are obtained with a planar diode driven with a 35ns Blumlein pulse line. Pepper pot images are observed with a fast phosphor and gated camera. The current density and beamlet divergence angle are uniform within +-10% and a brightness J = 1.6E10A/m/sup 2/rad/sup 2/ is observed at a current density j=44A/cm/sup 2/. 6 refs., 2 figs., 2 tabs.