Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Status of the ETA-II (Experimental Test Accelerator II) linear induction accelerator: High brightness results

Conference ·
OSTI ID:5200078
A two-aperture collimator has been used to measure brightness of the electron beam produced by the injector and the first 20 acceleration cells of the ETA-II linear induction accelerator. Osmium alloy dispenser cathodes produce the electron beam. For accelerated currents up to 1.5 kA with 2.0- to 2.7-MeV beam energies the measured brightness is 5 {times} 10{sup 9} A/(rad-m){sup 2}, exceeding our design goal by a factor of 2. At the highest current, 2.0 kA, a beam brightness of 2.6 {times} 10{sup 9} A/(rad-m){sup 2} has been measured. 6 refs., 5 figs., 2 tabs.
Research Organization:
Lawrence Livermore National Lab., CA (USA)
Sponsoring Organization:
DOD; DOE/DP
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
5200078
Report Number(s):
UCRL-99579-Rev.; CONF-890335--240-Rev.; ON: DE90003600
Country of Publication:
United States
Language: