Monitored summer peak attic air temperatures in Florida residences
Conference
·
OSTI ID:687677
- Florida Solar Energy Center, Cocoa, FL (United States)
The Florida Solar Energy Center (FSEC) has analyzed measured summer attic air temperature data taken for some 21 houses (three with two different roof configurations) over the last several years. The analysis is in support of the calculation within ASHRAE Special Project 152P, which will be used to estimate duct system conductance gains that are exposed to the attic space. Knowledge of prevailing attic thermal conditions are critical to the duct heat transfer calculations for estimation of impacts on residential cooling system sizing. The field data were from a variety of residential monitoring projects that were classified according to intrinsic differences in roofing configurations and characteristics. The sites were occupied homes spread around the state of Florida. There were a variety of different roofing construction types, roof colors, and ventilation configurations. Data at each site were obtained from June 1 to September 30 according to the ASHRAE definition of summer. The attic air temperature and ambient air temperature were used for the data analysis. The attic air temperature was measured with a shielded type-T thermocouple at mid-attic height, halfway between the decking and insulation surface. The ambient air temperature was obtained at each site by thermocouples located inside a shielded exterior enclosure at a 3 to 4 m (10--12 ft) height. The summer 15-minute data from each site were sorted by the average ambient air temperature into the top 2.5% of the observations of the highest temperature. Within this limited group of observations, the average outside air temperature, attic air temperature, and coincident difference were reported.
- OSTI ID:
- 687677
- Report Number(s):
- CONF-980650--
- Country of Publication:
- United States
- Language:
- English
Similar Records
Comparison between predicted duct effectiveness from proposed ASHRAE Standard 152P and measured field data for residential forced air cooling systems
Vented and sealed attics in hot climates
Comparison of a duct system computer model with measured data in a residential attic with a duct system
Technical Report
·
Sun Mar 31 23:00:00 EST 2002
·
OSTI ID:795371
Vented and sealed attics in hot climates
Conference
·
Wed Dec 30 23:00:00 EST 1998
·
OSTI ID:687678
Comparison of a duct system computer model with measured data in a residential attic with a duct system
Conference
·
Wed Dec 30 23:00:00 EST 1998
·
OSTI ID:687666