Thermotransport of hydrogen and deuterium in vanadium, niobium, and tantalum

Journal Article · · Metall. Trans., A; (United States)
DOI:https://doi.org/10.1007/BF02642395· OSTI ID:6856033

Thermotransport was toward the cold end of the sample, and redistribution increased with increasing atomic mass of the host metal. The heat of transport was greater for deuterium than for hydrogen. Thermotransport decreased as the temperature increased in tantalum and niobium. 31 refs.

Research Organization:
Iowa State Univ, Ames, USA
OSTI ID:
6856033
Journal Information:
Metall. Trans., A; (United States), Journal Name: Metall. Trans., A; (United States) Vol. 13A:5; ISSN MTTAB