skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Use of O-15 water and C-11 butanol to measure cerebral blood flow (CBF) and water permeability with positron emission tomography (PET)

Conference · · J. Nucl. Med.; (United States)
OSTI ID:6851740

Tracers used to measure CBF with PET and the Kety autoradiographic approach should freely cross the blood-brain barrier. 0-15 water, which is not freely permeable, may underestimate CBF, especially at higher flows. The authors determined this under-estimation relative to flow measured with a freely diffusible tracer, C-11 butanol and used these data to calculate the extraction (E) and permeability surface area product (PS) for 0-15 water. Paired flow measurements were made with 0-15 water (CBF-wat) and C-11 butanol (CBF-but) in eight normal human subjects. Average CBF-but, 55.6 ml/(min . 100g) was significantly greater than CBF-water, 47.6 ml/(min . 100g). The ratio of regional gray matter (GM) flow to white matter (WM) flow was significantly greater with C-11 butanol, indicating a greater underestimation of CBF with 0-15 water in the higher flow GM. Average E for water was 0.92 in WM and 0.82 in GM. The mean PS in GM, 148 ml/(min . 100g), was significantly greater than in WM, 94 ml/(min . 100g). Simulation studies demonstrated that a measurement error in CBF-wat or CBF-but causes an approximately equivalent error in E but a considerably larger error in PS due to the sensitivity of the equation, PS=-CBF . ln(1-E), to variations in E. Modest errors in E and PS result from tissue heterogeneity that occurs due to the limited spatial resolution of PET. The authors' measurements of E and PS for water are similar to data obtained by more invasive methods and demonstrate the ability of PET to measure brain water permeability.

Research Organization:
Washington Univ., School of Medicine, St. Louis, MO
OSTI ID:
6851740
Report Number(s):
CONF-850611-; TRN: 87-011085
Journal Information:
J. Nucl. Med.; (United States), Vol. 26:5; Conference: 32. annual meeting of the Society of Nuclear Medicine, Houston, TX, USA, 2 Jun 1985
Country of Publication:
United States
Language:
English

Similar Records

Positron emission tomographic measurement of cerebral blood flow and permeability-surface area product of water using (/sup 15/O)water and (/sup 11/C)butanol
Journal Article · Thu Oct 01 00:00:00 EDT 1987 · J. Cereb. Blood Flow Metab.; (United States) · OSTI ID:6851740

Positron imaging of intravenous O-15 labeled water for cerebral blood flow
Conference · Sun Jan 01 00:00:00 EST 1984 · J. Nucl. Med.; (United States) · OSTI ID:6851740

Brain blood flow measured with intravenous H/sub 2//sup 15/O. II. Implementation and validation
Journal Article · Thu Sep 01 00:00:00 EDT 1983 · J. Nucl. Med.; (United States) · OSTI ID:6851740