Treatment of coal gasification wastewater using rotating biological contactors. [Total organic carbon]

Technical Report ·
OSTI ID:6844138

Reuse of coal gasification process water for makeup cooling tower water requires physical, chemical and biological treatment to prevent excessive corrosion and bio-fouling in the tower. Pretreated wastewater contains about 2100 mg/l BOD, 5800 mg/l COD, 2000 mg/l TOC, 560 mg/l ammonia, 30 mg/l cyanide, 190 mg/l thiocyanate, 180 mg/l phenols, and 1700 mg/l hydantoins. Single-stage RBC treatment was effective in biotreatment of this wastewater even though feed strength was highly variable. Removals at a hydraulic loading of 1 gpd were 94% for BOD, 33.8% for COD, 33% for TOC, and 100% for phenols. Ammonia, thiocyanate, cyanide and hydantoins were not removed to any significant degree in this system. 6 references, 10 figures, 4 tables.

Research Organization:
North Dakota Univ., Grand Forks (USA)
DOE Contract Number:
FC21-83FE60181
OSTI ID:
6844138
Report Number(s):
DOE/FE/60181-50; CONF-840749-1; ON: DE84013302
Country of Publication:
United States
Language:
English