Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Space cell test program, life cycle tests. Monthly progress report

Technical Report ·
OSTI ID:6842947

Under normal operation, complete data were recorded every 32 cycles on the 90-minute and 3 hour packs. On the 24-hour packs, complete data were taken every eight cycles. Before cycling, each pack was given a capacity test at its respective cycling temperature. This consisted of a c/10 charge for 16 hours followed by a c/2 discharge to 1.0 volt per cell average. After 88 days of cycling, each pack was discharged immediately after the end of the regular cycle period, at the c/2 rate to 1.0 volt per cell average. The pack was then recharged at the c/10 rate for 16 hours and discharged at the c/2 rate to 1.0 volt per cell average. The pack was again recharged at the c/10 rate for 48 hours with voltage being limited to the cycle limits.

Research Organization:
Naval Ammunition Depot, Crane, IN (USA)
OSTI ID:
6842947
Report Number(s):
NASA-CR-64349
Country of Publication:
United States
Language:
English

Similar Records

Cycle life test of secondary spacecraft cells. Annual report 1
Technical Report · Fri May 14 00:00:00 EDT 1965 · OSTI ID:6779251

Space cell test program. Monthly progress report
Technical Report · Sun Nov 29 23:00:00 EST 1964 · OSTI ID:6930125

Cycle life test and failure model of nickel-hydrogen cells
Technical Report · Fri Dec 31 23:00:00 EST 1982 · OSTI ID:5510260