Motion detection and correction in Tl-201 SPECT imaging: A simple, practical method
Conference
·
· J. Nucl. Med.; (United States)
OSTI ID:6842943
Since Tl-201 SPECT imaging requires that pts remain in an awkward position for a prolonged time, pt motion (M) is a potentially serious source of artifactual defects on tomographic (tomo) reconstructions. Thus the authors developed a simple method for detection and correction of M from SPECT images. A Co-57 point source is placed on the lower anterior chest, an area remaining in the camera's field of view throughout imaging, and is imaged concurrently with Tl. In the absence of M, this point source inscribes a straight line on planar summation of the 32 projections over 180/sup 0/. Movement is detected by deviation from this line. The number of pixels (P) of M is used to shift images so that the resultant images of the point source are linear. The method was tested in 48 consecutive patients undergoing Tl tomo. Uncorrected and corrected images were reconstructed, and long- and short-axis tomo cuts were quantitatively analyzed using circumferential profiles (CPs) of maximum counts with comparison to lower limits of normal. Extent (E) of abnormality was expressed as the % of CP points falling below normal. M was detected in 8/48 pts (17%) and was 2 P in 3 and 1 P in 5 pts. E was less following correction in 7/8 pts, with a mean decrease of 71% with 2 PM and 44% with 1 PM. Visual change in tomo after correction was dramatic with 2 PM and subtle with 1 PM. The E and location of tomo abnormality after correction more closely resembled subsequent planar imaging than did the uncorrected reconstructions. The authors conclude: 1) pt M is a common problem in SPECT Tl images; 2) when > 1 pixel, M results in major tomographic artifacts; and 3) the method described provides a simple practical approach for detection and correction of M.
- Research Organization:
- Cedars-Sinai Medical Center, Los Angeles, CA
- OSTI ID:
- 6842943
- Report Number(s):
- CONF-840619-
- Conference Information:
- Journal Name: J. Nucl. Med.; (United States) Journal Volume: 25:5
- Country of Publication:
- United States
- Language:
- English
Similar Records
Patient motion in thallium-201 myocardial SPECT imaging. An easily identified frequent source of artifactual defect
Quantitative analysis of the tomographic thallium-201 myocardial bullseye display: critical role of correcting for patient motion
Quantification of the extent and severity of myocardial ischemia in single-vessel disease using stress-redistribution thallium-201 single-photon emission computerized tomography
Journal Article
·
Sun May 01 00:00:00 EDT 1988
· Clin. Nucl. Med.; (United States)
·
OSTI ID:7187273
Quantitative analysis of the tomographic thallium-201 myocardial bullseye display: critical role of correcting for patient motion
Journal Article
·
Thu Dec 31 23:00:00 EST 1987
· J. Nucl. Med.; (United States)
·
OSTI ID:5560324
Quantification of the extent and severity of myocardial ischemia in single-vessel disease using stress-redistribution thallium-201 single-photon emission computerized tomography
Conference
·
Sat Dec 31 23:00:00 EST 1983
· J. Nucl. Med.; (United States)
·
OSTI ID:6843043
Related Subjects
550601 -- Medicine-- Unsealed Radionuclides in Diagnostics
550602* -- Medicine-- External Radiation in Diagnostics-- (1980-)
62 RADIOLOGY AND NUCLEAR MEDICINE
ACCURACY
BETA DECAY RADIOISOTOPES
BODY
BODY AREAS
CHEST
COBALT 57
COBALT ISOTOPES
COMPUTERIZED TOMOGRAPHY
CORRECTIONS
DAYS LIVING RADIOISOTOPES
DIAGNOSTIC TECHNIQUES
DIAGNOSTIC USES
ELECTRON CAPTURE RADIOISOTOPES
EMISSION COMPUTED TOMOGRAPHY
HEAVY NUCLEI
IMAGE PROCESSING
IMAGES
INTERMEDIATE MASS NUCLEI
ISOMERIC TRANSITION ISOTOPES
ISOTOPES
MOTION
NUCLEI
ODD-EVEN NUCLEI
PATIENTS
POSITIONING
PROCESSING
RADIOISOTOPES
SECONDS LIVING RADIOISOTOPES
SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY
THALLIUM 201
THALLIUM ISOTOPES
TOMOGRAPHY
USES
550602* -- Medicine-- External Radiation in Diagnostics-- (1980-)
62 RADIOLOGY AND NUCLEAR MEDICINE
ACCURACY
BETA DECAY RADIOISOTOPES
BODY
BODY AREAS
CHEST
COBALT 57
COBALT ISOTOPES
COMPUTERIZED TOMOGRAPHY
CORRECTIONS
DAYS LIVING RADIOISOTOPES
DIAGNOSTIC TECHNIQUES
DIAGNOSTIC USES
ELECTRON CAPTURE RADIOISOTOPES
EMISSION COMPUTED TOMOGRAPHY
HEAVY NUCLEI
IMAGE PROCESSING
IMAGES
INTERMEDIATE MASS NUCLEI
ISOMERIC TRANSITION ISOTOPES
ISOTOPES
MOTION
NUCLEI
ODD-EVEN NUCLEI
PATIENTS
POSITIONING
PROCESSING
RADIOISOTOPES
SECONDS LIVING RADIOISOTOPES
SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY
THALLIUM 201
THALLIUM ISOTOPES
TOMOGRAPHY
USES