Measuring tracee turnover from tracer specific activity in the steady state
Journal Article
·
· Am. J. Physiol.; (United States)
OSTI ID:6824433
When a substrate appears in and disappears from an unmeasured (tissue) compartment, the proper sites for tracer infusion and sampling to measure tracee turnover become controversial. We analyze a three-compartment model representing arterial blood, tissue, and venous blood. The desired quantity, tracee turnover, is the ratio of the steady-state infusion rate to tissue specific activity. However, specific activity in the tissue compartment is unknown. We assume infusion of tracer into the arterial pool at a constant rate and consider sampling of specific activity of either blood compartment in the steady state. We obtain estimates of tissue specific activity from measurement of concentrations of tracer and tracee in blood samples in two extreme cases. In case I, tracee is assumed to appear in the venous compartment but to disappear from the tissue pool. Then tissue specific activity is equal to arterial specific activity. In case II, both appearance and disappearance are from the tissue pool. Tissue specific activity is then less than arterial or venous specific activity. We give formulas for the difference in each case. We discuss the relationship of our models to actual tracer experiments and define physiological locations for our three compartments. Appearance of substrates is probably intermediate between our extreme cases. A numerical estimate of turnover for the substrate lactate in resting humans reveals an error bound of approximately 30%. We discuss sites of infusion and sampling consistent with our model, the effects of relaxing some of our modeling constraints, and experimental necessities for getting beyond the steady state.
- Research Organization:
- Univ. of California, Berkeley (USA)
- OSTI ID:
- 6824433
- Journal Information:
- Am. J. Physiol.; (United States), Journal Name: Am. J. Physiol.; (United States) Vol. 255; ISSN AJPHA
- Country of Publication:
- United States
- Language:
- English
Similar Records
Tracer measured substrate turnover requires arterial sampling downstream of infusion site
Tracer studies with aortic infusion result in improper tracer distribution
Use of a variable tracer infusion method to determine glucose turnover in humans
Conference
·
Tue Mar 04 23:00:00 EST 1986
· Fed. Proc., Fed. Am. Soc. Exp. Biol.; (United States)
·
OSTI ID:7119069
Tracer studies with aortic infusion result in improper tracer distribution
Conference
·
Tue Mar 04 23:00:00 EST 1986
· Fed. Proc., Fed. Am. Soc. Exp. Biol.; (United States)
·
OSTI ID:6942271
Use of a variable tracer infusion method to determine glucose turnover in humans
Journal Article
·
Sun Dec 31 23:00:00 EST 1989
· American Journal of Physiology; (USA)
·
OSTI ID:7191472
Related Subjects
551001* -- Physiological Systems-- Tracer Techniques
59 BASIC BIOLOGICAL SCIENCES
ALGORITHMS
ANIMAL TISSUES
ARTERIES
BIOLOGICAL MATERIALS
BLOOD
BLOOD VESSELS
BODY
BODY FLUIDS
CARDIOVASCULAR SYSTEM
ISOTOPE APPLICATIONS
ISOTOPES
MATERIALS
MATHEMATICAL LOGIC
MATHEMATICAL MODELS
ORGANS
RADIOISOTOPES
STEADY-STATE CONDITIONS
SUBSTRATES
TISSUES
TRACER TECHNIQUES
VEINS
59 BASIC BIOLOGICAL SCIENCES
ALGORITHMS
ANIMAL TISSUES
ARTERIES
BIOLOGICAL MATERIALS
BLOOD
BLOOD VESSELS
BODY
BODY FLUIDS
CARDIOVASCULAR SYSTEM
ISOTOPE APPLICATIONS
ISOTOPES
MATERIALS
MATHEMATICAL LOGIC
MATHEMATICAL MODELS
ORGANS
RADIOISOTOPES
STEADY-STATE CONDITIONS
SUBSTRATES
TISSUES
TRACER TECHNIQUES
VEINS