Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Full-scale scrubber characterization of Colstrip Unit 2. Final report

Technical Report ·
OSTI ID:6805950
The flue gas desulfurization system at Montana Power Company Colstrip Unit 2 was characterized by field testing and engineering analysis. The characterization included measurement of currently regulated as well as unregulated emissions in the gas, liquid, and solid effluent streams of the sulfur dioxide scrubber system. Sulfur dioxide, nitrogen oxides, particulate, fine particulate, trace elements, particle size-segregated trace element distribution, sulfuric acid mist, chlorides, fluorides, organics, carbon monoxide, and carbon dioxide were all measured in the scrubber system influent and effluent streams. In addition, mist eliminator performance, scrubber generated particulate, and scrubber sludge characterization testing and analyses were performed. A significant part of the program was devoted to establishing the applicability of measurement techniques and the quality and limitations of the resultant data. A discussion of the scrubber process chemistry based on the system performance data gathered is presented. An engineering and economic analysis of the scrubber system is included. Sulfur dioxide removal efficiencies from 82 to 88% were found over a limited range of scrubber liquid-to-gas ratios and recirculating solids content for the Colstrip Unit 2 fly ash-lime scrubbing system. Particulate removal was measured at about 99% across the scrubber system. The capital cost of the scrubber system, additive preparation system, and sludge disposal system was about $69/kW in 1977. The annual operating cost was 4.5 mills/kWh for 1979. Major operational problem areas have included the slurry preparation system and scrubber vessel lining. The scrubber system availability has averaged about 86%.
Research Organization:
Black and Veatch Consulting Engineers, Kansas City, MO (USA)
OSTI ID:
6805950
Report Number(s):
EPRI-CS-2764; ON: DE83901129
Country of Publication:
United States
Language:
English

Similar Records

Full-scale scrubber characterization of Conesville Unit 5. Final report
Technical Report · Sun Aug 01 00:00:00 EDT 1982 · OSTI ID:6924278

Colstrip scrubber tops 90% availability for one year
Journal Article · Tue Feb 28 23:00:00 EST 1978 · Electr. Light Power (Boston); (United States) · OSTI ID:5028152

Flue gas desulfurization/The Colstrip flue gas cleaning system
Journal Article · Tue Jan 31 23:00:00 EST 1978 · Chem. Eng. Prog.; (United States) · OSTI ID:5228891