Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Electric penetration assemblies in containment structures for light-water-cooled nuclear power plants. Revision 2, July 1978

Book ·
OSTI ID:6766938
Appendix A to 10 CFR Part 50, Criterion 50 (Containment Design Basis) requires that the reactor containment structure be designed so that it can accommodate conditions resulting from any loss-of-coolant accident; Appendix B to 10 CFR Part 50 establishes pertinent quality assurance requirements. This guide provides an acceptable method for complying with these regulations with respect to the mechanical, electrical and test requirements for the design, qualification, construction, installation and testing of electric penetration assembly in containment structures of light-water-cooled nuclear power plants. Consultation was provided by the Advisory Committee on Reactor Safeguards.
OSTI ID:
6766938
Report Number(s):
REG/G-1.63
Country of Publication:
United States
Language:
English